Dynalco UM-600 Universal Monitor Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 23
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
21
302048
-
302049
2047
-
2048
Channel 6 High Low Limit
-
9999.0
99999.0
32 bit Float(IEEE 754)
302050
-
302051
2049
-
2050
Channel 1 and 2 Differential Low
Alarm Limit
-
9999.0
99999.0
32 bit Float(IEEE 754)
302052
-
302053
2051
-
2052
C
hannel 3 and 4 Differential Low
Alarm Limit
-
9999.0
99999.0
32 bit Float(IEEE 754)
302054
-
302055
2053
-
2054
Channel 5 and 6 Differential Low
Alarm Limit
-
9999.0
99999.0
32 bit Float(IEEE 754)
302056
-
302057
2055
-
2056
RPM
0
99999.0
32 bit unsigned integer
302058
-
302059
2057
-
2058
Hourmeter
0
99999.0
32 bit unsigned integer
Holding Register Table (table 2)
Modicon
Address
Modbus
Offset
Description
Min
Value
Max
Value
Data type
401001
-
401002
1000
-
1001
Log start date (upper 16 bits
and lower 16 bits
respectively)
Custom (See table 3)
Date Format Table (table 3)
Second(MSB)
Minute
Hour
Day
Month
Year(LSB)
Bits
6
6
5
5
4
6
Value
range
0-59
0-59
0-23
1-31
1-12
0-63(relative to year
2000)
Log Buffer Entry (table 4)
Datetime
Event ID
Value
Length
32 bit unsigned
integer
16 bit unsigned
integer
32 bit Float(IEEE 754)
Value
range
See table 3
1-10
-9999.0 – 99999.0
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23